Qu-041407 De-Accessing accessed implanted port
Enroll
Type
Quiz
Credit
No
Description
De-accessing an implanted venous port is a sterile procedure performed to safely remove a non-coring ... show more
De-accessing an implanted venous port is a sterile procedure performed to safely remove a non-coring (Huber) needle from an accessed port following completion of therapy. This process requires adherence to strict aseptic technique to prevent infection, proper flushing and locking of the device per protocol, and application of an appropriate dressing to maintain site integrity. The nurse must ensure patient safety and comfort, and monitor for complications such as bleeding, occlusion, or signs of infection. show less
Objectives
- Apply appropriate dressing and ensure hemostasis at the site.
- Assess the site post-procedure for bleeding, swelling, pain, or signs of infection
- Demonstrate proper aseptic technique throughout the de-accessing procedure to minimize infection risk.
- Describe indications for de-accessing an implanted port, including completion of therapy and provider orders.
- Document the procedure accurately, including site assessment, patient tolerance, and any complications.
- Identify required supplies and prepare equipment appropriately prior to the procedure.
- Perform correct flushing and locking technique per institutional protocol (e.g., saline and/or heparin lock).
- Safely remove the non-coring needle while maintaining stabilization of the port